Electrical connections for installation

Electrical connections for installation

Before proceeding with the physical installation of the chain system, it is essential to prepare the power supply connections.

1. Power Supply to Master Unit

The primary connection involves supplying power to the master unit. Use a 230V-50Hz power source (or 110V-60Hz for installations in regions using the US power grid).
Connection terminals are clearly labeled on the diagram:

  • F – Phase

  • N – Neutral

  • Ground – Marked with the standard ground symbol


2. Motor Connection to Slave Unit

The slave unit contains only the motor and operates in sync with the motor in the master unit. To enable this simultaneous operation, you must connect the terminals marked + and - for Motor 2 on the master unit to the corresponding + and - terminals on Motor 2 in the slave unit.
Refer to the provided diagram for the exact position of the Motor 2 connections in the master unit.


3. Cable Size Requirements for Motor 2 Connection

The cross-section of the cables used for connecting Motor 2 depends on the distance between the master and slave units:

  • Up to 5 meters: Use cables with a minimum cross-section of 1.5 mm²

  • From 5 to 18 meters: Use cables with a minimum of 2.5 mm²

  • For long distances (18–20 meters): Use cables with a cross-section of at least 5 mm²

Recommendation: For optimal performance and simplified installation, we recommend using 2.5 mm² cables for all distances except for long-distance connections (above 18 meters), where 5 mm² cables should be used.

Ensure all cables are suitable for outdoor use and comply with local electrical codes and safety standards.

    • Related Articles

    • Electrical connections - Wiring diagram

    • How to install Chain Column

      Instructions for installing Chain column: 1. Screw in for 1,5 - 2,0 cm the 4 screws M10x70 in dotation to the base. 2. Place the base on the previously prepared base of cement (Fig.3) 3. The upper part of the base should be clean and perfectly ...
    • Parklio Chain - No option in App

      If you have screen like this for Parklio Chain, you should check IO0 and IO1 connections on Parklio Brain and Chain's control board. It is probably loose contact. Secure it and try again.
    • How to Calibrate the Chain?

      (Note: Parklio™ Chains come pre-calibrated from the factory. Calibration is only required if the chain length has been changed or adjusted. In some cases due to transport and installation Chain is required to be calibrated) Step-by-Step Calibration ...
    • 🔌 Powering the Parklio™ Chain Barrier

      After installation, the Parklio™ Chain Barrier must be connected to a power supply. Please follow the instructions below to ensure correct setup. 1. Powering the Master Unit The master unit operates on a 230V power supply. Refer to the image provided ...