Parklio Chain
How to Bypass Photocells on Chain
⚠️ Warning: Bypassing photocells removes safety detection — the Chain will operate without obstacle detection. This should only be done for testing/diagnostic purposes or if photocells are not installed. Method 1: Hardware Bypass (Jumper) If ...
Chain RFID Wiring Diagram
You can also find the photo of Chain RFID Wiring diagram at the following link: https://file.parklio.co/file/fsz0gbbc6cd66d27144919693f6efc0b7bd10
Chain Installation Guide: Power Supply, Master/Slave Setup & Photocells
Before installing the Chain unit itself, it is necessary to complete the power supply installation and connect the master and slave units according to the instructions provided in the user manual. Proper preparation ensures smooth operation and ...
Slave Unit Does Not Fully Close – Power Supply Cable Check
If the slave unit of the Parklio™ Chain Barrier does not fully close, the most common cause is an insufficient or incorrect power supply cable between the master and slave units. Possible Cause The slave unit may not be receiving enough power due to: ...
Troubleshooting Calibration Issues on Parklio™ Chain
If you perform a calibration on the Chain barrier but the correct position is not displayed in the app — and you receive messages that the barrier is opening or closing followed by a timeout error — the first step is to check the magnetic switch. How ...
Electrical Connections for Installation
Before proceeding with the physical installation of the chain system, it is essential to prepare the power supply connections. 1. Power Supply to Master Unit The primary connection involves supplying power to the master unit. Use a 230V-50Hz power ...
Powering the Parklio Chain Barrier
After installation, the Parklio Chain Barrier must be connected to a power supply. Please follow the instructions below to ensure correct setup. 1. Powering the Master Unit The master unit operates on a 230V power supply. Refer to the image provided ...
How to Enable Auto-Close on Parklio Chain
The Auto-Close feature is available for Parklio Chain, but it must be enabled manually via the control board, as it is not configurable through the app. How to Enable Auto-Close Follow these steps to set up Auto-Close on your Parklio Chain: Remove ...
Chain Power Outputs: Understanding the Details
Chain control boards come equipped with two distinct power outputs, each designed for specific components in your system. Understanding their specifications ensures proper operation and safe integration of devices. Output 1 & 2: Flashing Light and ...
Tensile Strength of Chain and Failure Tension of Safety Joint
Parklio steel chain is guaranteed to withstand up to 300 kg of tension (nominal value). The safety joint is designed to release the chain when the tension reaches a critical point. Under tension, the screw in the joint bends, allowing the chain to ...
How to Add Remote for Chain
Press and release the RED button. The flashing LED will remain constantly lit. ↳ IF NOT - Check that the chain is completely closed (UP) and that the SW1 is in position AUTO, repeat again from the beginning. Press the 1st button on the remote ...
Parklio Chain - Possible Problems And Solutions
Type of problem Probable cause Solution On activating the opening command the automation does not move. Lack of electrical power supply Check the presence of the electrical voltage and all the connections to the electrical network. On activating the ...
Enabling and disabling the pre-flashing, photocell test and the multi-user function
To modify the status of any of these functions it is necessary to enable the setting mode. In the phase of learning the control unit automatically goes through all possible functions in which it is possible to intervene. The led of the f lashing ...
Parklio Chain Electrical Connections - Wiring Diagram
You can also find the Parklio Chain wiring diagram at the following link: https://file.parklio.co/file/pawna5c002f27a98c4c56bdd8d84e7101c186
Parklio Chain - Optimum Height of Chain Depending on Chain Lenght
The Parklio Chain consists of the following main components: Parking post Control unit Profile for the chain Chain You can also find the image of components of Parklio Chain at the following link: ...
Chain Does Not Receive Commands From App or PMS
If you installed Chain and manual mode is working well, also you get true positions of Chain in App, but when you click lower or extend nothing is happening, please try next: On Parklio Brain device disconnect wire from - (minus, red on picture) and ...
Chain Stops Halfway in Automatic Mode
If the chain doesn’t go all the way up or down as it should when controlling the App, the problem is probably in switches inside the chain. Switches must be inspected and returned to their own position. There are two switches behind inner chain in ...
How to install Chain Column
Instructions for installing Chain column: 1. Screw in for 1,5 - 2,0 cm the 4 screws M10x70 in dotation to the base. 2. Place the base on the previously prepared base of cement (Fig.3) 3. The upper part of the base should be clean and perfectly ...
Manual Control of The Chain
Move the Chain to Manual mode on control board (Control board is located in master unit in the white plastic box). You can see the image of control board modules needed to switch the chain to manual mode at the following link: ...
Parklio Chain - Factory Reset
To successfully reset the Parklio Chain, follow the instructions below: Power off the chain (remove power supply). Press and hold the RED button. Reconnect the power supply while the RED button is pressed. The LED will start to flash, keep the RED ...
Chain is not rising or barely rising
A possible solution for this problem is to first increase the torque on the motor and do the calibration process after that. Note: If the torque screw is set to maximum then the potentiometer will got minimum and the torque will be lowered instead of ...
Parklio Chain - No option in App
If you see the screen below in the Parklio Connect app for Parklio Chain, please check the IO0 and IO1 connections between the Parklio Brain and the Chain control board. The issue is most likely caused by a loose contact. Secure the connections and ...