Parklio Chain - Possible Problems And Solutions

Parklio Chain - Possible Problems And Solutions

Type of problemProbable causeSolution
On activating the opening command the automation does not move.Lack of electrical power supplyCheck the presence of the electrical voltage and all the connections to the electrical network.
On activating the opening command the automation does not move.Burned fuseReplace the fuse with a similar one.
On activating the opening command the chain moves for a brief time and then stops.Incorrect encoder connectionCheck the connections of the encoder’s wires.
On activating the opening command, the automation moves to closure.Jumper direction motor invertedInvert the Jumpers.
You cannot manage to enter into the remote control learning phaseThe chain is not completely closed (UP)Close the chain (in the manual). If the chain was closed set selector S1 to manual, wait 1 second and reset it to automatic. Try again entering into setting mode.
You cannot manage to memorize the remote controlsThe type of set decoding in the control panel does not correspond to the type of remote control in use.Check which decoding has been set and possibly select that which corresponds to the remote control in use.
You cannot manage to enter into the opening/ closure programming mode. (run-time)The chain is not completely closed (UP)Close the chain (in the manual). If the chain was closed set selector S1 to manual, wait 1 second and reset it to automatic. Try again entering into setting mode.
The control panel is powered but the gate does not move.A normally closed input is not activeCheck the photocell, stop and limit switch input. If not used they must be bridged to the common.