Factory reset

Factory reset

  1. Power of the chain (remove power supply).

  2. Press and hold the RED button.

  3. Reconnect the power supply while the RED button is pressed.

  4. The LED will start to flash, keep the RED button pressed until the LED lights up for the 3rd time.

  5. Release the button and wait for the LED to turn off.

  6. Reset is complete.

    • Related Articles

    • How to Calibrate the Chain?

      (Note: Parklio™ Chains come pre-calibrated from the factory. Calibration is only required if the chain length has been changed or adjusted. In some cases due to transport and installation Chain is required to be calibrated) Step-by-Step Calibration ...
    • Chain is not rising or barely rising