Connecting two Gates X to work in synchro mode

Connecting two Gates X to work in synchro mode

Please check out wiring diagram for connecting two Gates X version in synchro mode.
Brain device has no adjustment and in this case Gates are working over App and remotes for opening. Closing should be set up to automatic.


    • Related Articles

    • How to Connect Two Gates to Operate Simultaneously

      To synchronize two gates so they operate at the same time, follow these steps: 1. Connect the Bus Terminals Begin by connecting the bus terminals of the master and slave control units. Important: Ensure that both control units are powered off, and ...
    • Connecting LED stripe to Gate X

      Connecting an LED Strip to Gate X To connect an LED strip to Gate X, an additional relay must be installed if the client requires advanced LED strip functionality. This allows the LED strip to operate based on specific barrier states or logic. Below ...
    • Connecting photocells

      For all Gates we use Hiland P5141 Photocells. They are connected on Gate's control board like this: 1. Power supply From 12V-24V to 24 (Nr. 14) and COM (Nr. 13) 2. Signal From Photo to COM (Nr. 25) i FT(Nr. 24)
    • Parklio Gates dimensions

      Parklio Gates come in few dimensions but also should be noted that every dimension is possible and there are endless combinations for arm length. You can always send your request to our sales department and check availability, prices and delivery ...
    • Connecting Brain device to Gate - wiring diagram

      Please find below all the details of connecting Brain device to Gate: For any other question about wiring and connection details please contact support@parklio.com